Scanned sites / www.weitzelectric.com / 2026-10-02-2212

www.weitzelectric.com scan from 10/2/2026, 10:12:19 PM

Scan 2026-10-02-2212

Scanned 10/2/2026, 10:12:19 PM, finished 10/2/2026, 11:09:10 PM. Found on page 3 of brave web search results

Site: https://www.weitzelectric.com/

Download SQLite databaseEvery page and asset from this scan, with the crawl events, in one file.

76/ 100Good

On October 2, 2026 the Site Spider crawled 17 pages and 189 assets of www.weitzelectric.com, starting from https://www.weitzelectric.com/. It scored 76 out of 100, a good result. 10 of 16 checks found something to fix, led by meta descriptions (16), heavy assets (12), title tags (6); 4 checks passed. Most of the points went to meta descriptions (−8), heavy assets (−6), title tags (−3.8). 2 checks found something the score does not count, listed as noted. The list below shows each check's result, the fix plan, when present, explains what to do first, and the security review at the end of the page covers headers, transport, libraries and exposed files.

Security review: Medium3 medium, 3 low and 1 info findings. See the security findings ↓

Pages crawled
17
Assets fetched
189
Status
Completed
Checks with issues
10 of 16
CoverageComplete crawl

206 of 206 discovered URLs were fetched. The crawl reached everything it found. HTML only: nothing here ran JavaScript. 4 link destinations on other sites were checked.

  • Title tags6 issues
    6 of 16 pages have title issues.
    −3.8 points
  • Meta descriptions16 issues
    16 of 16 pages have meta description issues.
    −8 points
  • Headings8 issues
    8 of 16 pages have heading issues.
    −3 points
  • Broken links1 issue
    7 internal links point at 1 broken URL.
    −1.3 points
  • Links to other sites1 issue
    1 destination answered with an error, 1 could not be determined (timeouts, rate limits or refusals), of 4 destinations checked.
    −0.4 points
  • Redirects1 noted
    1 redirecting URL, 0 of them chained.
  • Non-200 responses1 issue
    2 URLs did not return a 2xx response. 1 of them is a page, 1 with an error status; the rest are assets or redirects.
    −0.6 points
  • Rate limitedOK
    The site did not rate limit the crawler.
  • IndexabilityOK
    0 of 16 indexable pages have indexability warnings.
  • Image alt textOK
    0 of 125 image references have no alt attribute. 125 use an empty alt (decorative), which is fine.
  • Heavy assets12 issues
    12 assets larger than 500 KB among 189 fetched assets.
    −6 points
  • Orphan pages1 issue
    1 page have no internal links pointing at them.
    −0.3 points
  • Sitemap coverage1 issue
    3 sitemaps listing 16 URLs: 0 crawled pages missing, 0 listed URLs broken or redirecting, 1 reachable only via the sitemap.
    −0.4 points
  • Internal link countsOK
    Internal link counts for 16 pages.
  • Thin content2 issues
    2 of 16 pages have fewer than 200 words.
    −1 points
  • Duplicate contentOK
    0 groups of pages with identical HTML.

Where this scan sits among all scanned sites

1860 sites, median 80%, average 79%

www.weitzelectric.com scores 76%, higher than 32% of the 1860 scanned sites. See the full ranking.

0541070%: 0 sites1%: 0 sites2%: 0 sites3%: 0 sites4%: 0 sites5%: 0 sites6%: 0 sites7%: 0 sites8%: 0 sites9%: 0 sites10%: 0 sites11%: 0 sites12%: 0 sites13%: 0 sites14%: 0 sites15%: 0 sites16%: 0 sites17%: 0 sites18%: 0 sites19%: 0 sites20%: 0 sites21%: 1 site22%: 0 sites23%: 0 sites24%: 0 sites25%: 0 sites26%: 0 sites27%: 0 sites28%: 1 site29%: 0 sites30%: 0 sites31%: 0 sites32%: 0 sites33%: 0 sites34%: 0 sites35%: 2 sites36%: 1 site37%: 2 sites38%: 2 sites39%: 1 site40%: 2 sites41%: 1 site42%: 0 sites43%: 1 site44%: 0 sites45%: 3 sites46%: 2 sites47%: 3 sites48%: 2 sites49%: 7 sites50%: 4 sites51%: 5 sites52%: 8 sites53%: 6 sites54%: 7 sites55%: 4 sites56%: 6 sites57%: 6 sites58%: 13 sites59%: 6 sites60%: 10 sites61%: 12 sites62%: 16 sites63%: 16 sites64%: 11 sites65%: 20 sites66%: 20 sites67%: 36 sites68%: 30 sites69%: 26 sites70%: 38 sites71%: 40 sites72%: 55 sites73%: 52 sites74%: 49 sites75%: 59 sites76%: 73 sites77%: 72 sites78%: 86 sites79%: 65 sites80%: 91 sites81%: 107 sites82%: 84 sites83%: 86 sites84%: 86 sites85%: 61 sites86%: 71 sites87%: 61 sites88%: 65 sites89%: 54 sites90%: 34 sites91%: 36 sites92%: 28 sites93%: 15 sites94%: 13 sites95%: 12 sites96%: 7 sites97%: 8 sites98%: 2 sites99%: 2 sites100%: 55 sites76% here100%90%80%70%60%50%40%30%20%10%0%

Green 90% and up (Excellent), lime 75 to 89 (Good), amber 50 to 74 (Needs work), red below 50 (Poor).

Internal link map

Loading the link map...

Start page (centre)OKRedirectErrorOrphanLinked from most pagesOne inbound link or noneRings = clicks from the start page. Size = inbound links. Drag to pan, scroll to zoom, click a page to see only its links.

Fix plan

Written by gpt-4o-mini from the scan findings

Your site has issues such as broken links and missing meta descriptions that need addressing to improve SEO. Prioritize fixes that can deliver the greatest impact with minimal effort.

  1. 1

    Fix Broken Links

    Why: Broken links harm user experience and SEO rankings.

    How: Update or remove links on pages like https://www.weitzelectric.com/blogs/our-top-10-favourite-no-fail/ directing to the broken URL.

    Checks: broken-links

  2. 2

    Improve Meta Descriptions

    Why: All pages lack meta descriptions, affecting click-through rates.

    How: Write unique meta descriptions for 9 pages, ensuring they summarize content and include keywords.

    Checks: meta-descriptions

  3. 3

    Address Non-200 Responses

    Why: URLs not returning 200 affect site accessibility and SEO.

    How: Check the page https://www.weitzelectric.com/2023/05/10/ and fix the 404 error by updating links or redirecting appropriately.

    Checks: status-codes

  4. 4

    Add Headings

    Why: Missing H1 tag affects content structure and SEO.

    How: Ensure each of the 8 pages lacking H1 tags include this critical heading for better search visibility.

    Checks: headings

  5. 5

    Shrink Heavy Assets

    Why: Large assets can slow down your site performance and affect SEO.

    How: Optimize images like those from https://www.weitzelectric.com/wp-content/uploads/2023/05/Rectangle-17961.png to reduce file size.

    Checks: heavy-assets

  6. 6

    Link Orphan Pages

    Why: Orphan pages don’t benefit from internal linking, limiting SEO potential.

    How: Add internal links to https://www.weitzelectric.com/blog/ from relevant pages to ensure search engines can discover it.

    Checks: orphan-pages

Generated automatically; verify each change against your own site before relying on it.

Security review

Written by gpt-4o-mini from 16 checks over the crawl

The website has multiple security issues that need addressing, primarily involving missing security headers which can increase vulnerability to attacks. Immediate action to implement the required headers is recommended to enhance overall site security.

  • 0 high
  • 3 medium
  • 3 low
  • 1 info
  1. 1

    Missing HTTP Strict Transport Security (HSTS)Medium

    Why it matters: No HSTS header means users can be intercepted when accessing the site via HTTP.

    Fix: Add 'Strict-Transport-Security: max-age=63072000; includeSubDomains; preload' to all pages.

    Evidence: HTTP Strict Transport Security

  2. 2

    Missing Content Security Policy (CSP)Medium

    Why it matters: Without CSP, the site is vulnerable to script injections and data theft.

    Fix: Implement a CSP header like 'Content-Security-Policy: default-src 'self'; script-src 'self' www.googletagmanager.com cdn.trustindex.io;'.

    Evidence: Content Security Policy

  3. 3

    Missing X-Frame-OptionsMedium

    Why it matters: Absence of this header allows clickjacking attacks through framing

    Fix: Add 'X-Frame-Options: DENY' to prevent the site from being iframed.

    Evidence: Clickjacking protection

  4. 4

    Missing X-Content-Type-OptionsLow

    Why it matters: Not using this header may lead to MIME-type sniffing attacks.

    Fix: Set the header 'X-Content-Type-Options: nosniff' on all HTML pages.

    Evidence: MIME sniffing protection

  5. 5

    Missing Referrer PolicyLow

    Why it matters: Without this header, sensitive URL paths may be exposed.

    Fix: Add 'Referrer-Policy: no-referrer' to restrict referrer information.

    Evidence: Referrer policy

  6. 6

    Third-party scripts without Subresource IntegrityLow

    Why it matters: Running scripts from external domains without SRI increases risk of compromise.

    Fix: Consider using Subresource Integrity or implement a CSP that allows only trusted hosts.

    Evidence: Third-party scripts

  7. 7

    Missing Permissions PolicyInfo

    Why it matters: Lack of this policy leaves browser features like camera and microphone open to misuse.

    Fix: Implement 'Permissions-Policy: notAllowed' if those features are unused.

    Evidence: Permissions policy

What the checks found

  • FoundHTTP Strict Transport SecurityMedium

    No HTML page sends strict-transport-security. Without it a visitor who types the address without https:// can be intercepted on the first request.

    • https://www.weitzelectric.com/ → no strict-transport-security
    • https://www.weitzelectric.com/about/ → no strict-transport-security
    • https://www.weitzelectric.com/our-services/ → no strict-transport-security
    • https://www.weitzelectric.com/home-automation/ → no strict-transport-security
    • https://www.weitzelectric.com/solar-and-permanent-soffit-lighting/ → no strict-transport-security
    • https://www.weitzelectric.com/residential/ → no strict-transport-security
    • https://www.weitzelectric.com/commercial/ → no strict-transport-security
    • https://www.weitzelectric.com/contact-us/ → no strict-transport-security
    • https://www.weitzelectric.com/blog/ → no strict-transport-security
    • https://www.weitzelectric.com/blogs/our-top-40-favourite-no-fail/ → no strict-transport-security
    • https://www.weitzelectric.com/blogs/our-top-30-favourite-no-fail/ → no strict-transport-security
    • https://www.weitzelectric.com/blogs/our-top-25-favourite-no-fail/ → no strict-transport-security
  • FoundContent Security PolicyMedium

    None of the 16 HTML pages send a Content-Security-Policy header or meta tag, so the browser has no restriction on where scripts, styles and frames may load from.

    • https://www.weitzelectric.com/ → no content-security-policy
    • https://www.weitzelectric.com/about/ → no content-security-policy
    • https://www.weitzelectric.com/our-services/ → no content-security-policy
    • https://www.weitzelectric.com/home-automation/ → no content-security-policy
    • https://www.weitzelectric.com/solar-and-permanent-soffit-lighting/ → no content-security-policy
    • https://www.weitzelectric.com/residential/ → no content-security-policy
    • https://www.weitzelectric.com/commercial/ → no content-security-policy
    • https://www.weitzelectric.com/contact-us/ → no content-security-policy
    • https://www.weitzelectric.com/blog/ → no content-security-policy
    • https://www.weitzelectric.com/blogs/our-top-40-favourite-no-fail/ → no content-security-policy
    • https://www.weitzelectric.com/blogs/our-top-30-favourite-no-fail/ → no content-security-policy
    • https://www.weitzelectric.com/blogs/our-top-25-favourite-no-fail/ → no content-security-policy
  • FoundClickjacking protectionMedium

    No HTML page sends x-frame-options. Without X-Frame-Options (or a CSP frame-ancestors directive) the pages can be embedded in a frame on another site and overlaid with invisible controls.

    • https://www.weitzelectric.com/ → no x-frame-options
    • https://www.weitzelectric.com/about/ → no x-frame-options
    • https://www.weitzelectric.com/our-services/ → no x-frame-options
    • https://www.weitzelectric.com/home-automation/ → no x-frame-options
    • https://www.weitzelectric.com/solar-and-permanent-soffit-lighting/ → no x-frame-options
    • https://www.weitzelectric.com/residential/ → no x-frame-options
    • https://www.weitzelectric.com/commercial/ → no x-frame-options
    • https://www.weitzelectric.com/contact-us/ → no x-frame-options
    • https://www.weitzelectric.com/blog/ → no x-frame-options
    • https://www.weitzelectric.com/blogs/our-top-40-favourite-no-fail/ → no x-frame-options
    • https://www.weitzelectric.com/blogs/our-top-30-favourite-no-fail/ → no x-frame-options
    • https://www.weitzelectric.com/blogs/our-top-25-favourite-no-fail/ → no x-frame-options
  • FoundMIME sniffing protectionLow

    No HTML page sends x-content-type-options. Without X-Content-Type-Options: nosniff a browser may run a file as a script because of its contents rather than its declared type.

    • https://www.weitzelectric.com/ → no x-content-type-options
    • https://www.weitzelectric.com/about/ → no x-content-type-options
    • https://www.weitzelectric.com/our-services/ → no x-content-type-options
    • https://www.weitzelectric.com/home-automation/ → no x-content-type-options
    • https://www.weitzelectric.com/solar-and-permanent-soffit-lighting/ → no x-content-type-options
    • https://www.weitzelectric.com/residential/ → no x-content-type-options
    • https://www.weitzelectric.com/commercial/ → no x-content-type-options
    • https://www.weitzelectric.com/contact-us/ → no x-content-type-options
    • https://www.weitzelectric.com/blog/ → no x-content-type-options
    • https://www.weitzelectric.com/blogs/our-top-40-favourite-no-fail/ → no x-content-type-options
    • https://www.weitzelectric.com/blogs/our-top-30-favourite-no-fail/ → no x-content-type-options
    • https://www.weitzelectric.com/blogs/our-top-25-favourite-no-fail/ → no x-content-type-options
  • FoundReferrer policyLow

    No HTML page sends referrer-policy. Without a Referrer-Policy the full page address, including any query string, is sent to every site a visitor clicks through to.

    • https://www.weitzelectric.com/ → no referrer-policy
    • https://www.weitzelectric.com/about/ → no referrer-policy
    • https://www.weitzelectric.com/our-services/ → no referrer-policy
    • https://www.weitzelectric.com/home-automation/ → no referrer-policy
    • https://www.weitzelectric.com/solar-and-permanent-soffit-lighting/ → no referrer-policy
    • https://www.weitzelectric.com/residential/ → no referrer-policy
    • https://www.weitzelectric.com/commercial/ → no referrer-policy
    • https://www.weitzelectric.com/contact-us/ → no referrer-policy
    • https://www.weitzelectric.com/blog/ → no referrer-policy
    • https://www.weitzelectric.com/blogs/our-top-40-favourite-no-fail/ → no referrer-policy
    • https://www.weitzelectric.com/blogs/our-top-30-favourite-no-fail/ → no referrer-policy
    • https://www.weitzelectric.com/blogs/our-top-25-favourite-no-fail/ → no referrer-policy
  • FoundPermissions policyInfo

    No HTML page sends permissions-policy. A Permissions-Policy header turns off browser features the site does not use (camera, microphone, geolocation), limiting what an injected script could do.

    • https://www.weitzelectric.com/ → no permissions-policy
    • https://www.weitzelectric.com/about/ → no permissions-policy
    • https://www.weitzelectric.com/our-services/ → no permissions-policy
    • https://www.weitzelectric.com/home-automation/ → no permissions-policy
    • https://www.weitzelectric.com/solar-and-permanent-soffit-lighting/ → no permissions-policy
    • https://www.weitzelectric.com/residential/ → no permissions-policy
    • https://www.weitzelectric.com/commercial/ → no permissions-policy
    • https://www.weitzelectric.com/contact-us/ → no permissions-policy
    • https://www.weitzelectric.com/blog/ → no permissions-policy
    • https://www.weitzelectric.com/blogs/our-top-40-favourite-no-fail/ → no permissions-policy
    • https://www.weitzelectric.com/blogs/our-top-30-favourite-no-fail/ → no permissions-policy
    • https://www.weitzelectric.com/blogs/our-top-25-favourite-no-fail/ → no permissions-policy
  • NoteThird-party scripts

    Scripts run from 2 other domains without Subresource Integrity, so a compromise of any of them changes what runs on this site. (Tag managers and analytics rarely support SRI; a Content-Security-Policy that names these hosts is the usual control.)

    • www.googletagmanager.com (16 script tags)
    • cdn.trustindex.io (1 script tag)
8 checks passed, 1 not applicable
  • OKHTTPS

    All 16 crawled pages were served over HTTPS.

  • OKSoftware version disclosure

    The Server header names a product without a version, and there is no X-Powered-By header.

  • OKMixed content

    No HTTPS page loads a script, stylesheet, font or image over plain HTTP.

  • OKForms over HTTPS

    11 forms found, all on HTTPS pages posting to HTTPS addresses.

  • OKVulnerable JavaScript libraries

    2 library versions recognised, none with known vulnerabilities.

  • OKKeys and secrets in page code

    No API keys, tokens or private keys were found in the sampled HTML and scripts.

  • OKExposed files and listings

    None of the crawled URLs is a configuration file, backup, dump, repository folder or directory listing.

  • OKSensitive paths in robots.txt

    robots.txt does not point at admin, backup or private paths.

  • Not applicableCookie flags

    The crawl set no cookies, so there are no cookie flags to check.

A passive review of what the crawl recorded: response headers, page and script contents and the URLs it found. It does not probe the site, test TLS settings or look for files that were not linked. Generated automatically; verify each finding against your own site before acting on it.

Sites scoring near www.weitzelectric.com

Their neighbours in the SEO rank table, which orders every scanned site by health score.

This report was produced by the DIY SEO Hub Site Spider crawling www.weitzelectric.com from its pages as published, the way a search engine does. It shows summary figures only.

Own www.weitzelectric.com?

  • Claim this site to manage the listing, hide it from the public lists, or keep it.
  • Want it gone instead? Ask through the support form or e-mail support@diyseohub.com, naming www.weitzelectric.com. Removal needs no account and no proof of purchase.
www.weitzelectric.com scan 2026-10-02-2212 | DIY SEO Hub